Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Clin Radiol ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38580482

RESUMO

AIM: This study aimed to assess the imaging features of atypical lipomatous tumors (ALTs) and lipoma with fat necrosis. METHODS: This study included patients with histopathologically proven fat necrosis within adipocytic tumors who underwent preoperative imaging. Magnetic resonance imaging (MRI) and/or computer tomography (CT) findings of fat necrosis associated with lipomatous tumors were retrospectively reviewed, emphasizing the "fatty island sign (FIS)." FISs were defined as well-demarcated, focal fat-containing areas surrounded by more thickened septa compared with other intratumoral septa. Imaging findings of FIS were compared between ALT and lipoma. RESULTS: Fat necrosis was histopathologically confirmed in 17 patients (6 ALTs and 11 lipomas). Among them, 18 FISs were observed in 10 lesions (59%). Multiple FISs within a lesion were observed in 4 (40%) patients. The median maximum diameter of the FISs was 37 mm. Hypointense areas within FISs relative to the subcutaneous fat on T1- and T2-weighted images were observed in 8 (80%) and 9 (90%), respectively, whereas hyperintense areas within FISs on fat-suppressed T2-weighted images were observed in 2 (20%). Nonfatty solid components within FISs were observed in 2 (20%). On CT, increased fat attenuation and pure fat attenuation within FISs were observed in 6 (86%) and 1 (14%), respectively. The imaging findings of FIS were not significantly different between ALT and lipoma. CONCLUSION: FISs were observed in 59% of the histologically proven ALT and lipoma patients with fat necrosis. The hypointense areas relative to the subcutaneous fat on T1- and T2-weighted images and increased fat attenuation on CT were usually observed within FISs.

2.
Clin Radiol ; 79(4): e554-e559, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38453389

RESUMO

AIM: To compare the radiation dose, image quality, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic protocol dual-energy computed tomography (CT) between two X-ray tubes mounted in the same CT machine. MATERIAL AND METHODS: This retrospective study comprised 80 patients (median age, 73 years; 45 men) who underwent pancreatic protocol dual-energy CT from January 2019 to March 2022 using either old (Group A, n=41) or new (Group B, n=39) X-ray tubes mounted in the same CT machine. The imaging parameters were completely matched between the two groups, and CT data were reconstructed at 70 and 40 keV. The CT dose-index volume (CTDIvol); CT attenuation of the abdominal aorta, pancreas, and PDAC; background noise; and qualitative scores for the image noise, overall image quality, and PDAC conspicuity were compared between the two groups. RESULTS: The CTDIvol was lower in Group B than Group A (7.9 versus 9.2 mGy; p<0.001). The CT attenuation of all anatomical structures at 70 and 40 keV was comparable between the two groups (p=0.06-0.78). The background noise was lower in Group B than Group A (12 versus 14 HU at 70 keV, p=0.046; and 26 versus 30 HU at 40 keV, p<0.001). Qualitative scores for image noise and overall image quality at 70 and 40 keV and PDAC conspicuity at 40 keV were higher in Group B than Group A (p<0.001-0.045). CONCLUSION: The latest X-ray tube could reduce the radiation dose and improve image quality in pancreatic protocol dual-energy CT.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Masculino , Humanos , Idoso , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Raios X , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
3.
Clin Radiol ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38403540

RESUMO

AIM: To evaluate arterial enhancement, its depiction, and image quality in low-tube potential whole-body computed tomography (CT) angiography (CTA) with extremely low iodine dose and compare the results with those obtained by hybrid-iterative reconstruction (IR) and deep-learning image-reconstruction (DLIR) methods. MATERIALS AND METHODS: This prospective study included 34 consecutive participants (27 men; mean age, 74.2 years) who underwent whole-body CTA at 80 kVp for evaluating aortic diseases between January and July 2020. Contrast material (240 mg iodine/ml) with simultaneous administration of its quarter volume of saline, which corresponded to 192 mg iodine/ml, was administered. CT raw data were reconstructed using adaptive statistical IR-Veo of 40% (hybrid-IR), DLIR with medium- (DLIR-M), and high-strength level (DLIR-H). A radiologist measured CT attenuation of the arteries and background noise, and the signal-to-noise ratio (SNR) was then calculated. Two reviewers qualitatively evaluated the arterial depictions and diagnostic acceptability on axial, multiplanar-reformatted (MPR), and volume-rendered (VR) images. RESULTS: Mean contrast material volume and iodine weight administered were 64.1 ml and 15.4 g, respectively. The SNRs of the arteries were significantly higher in the following order of the DLIR-H, DLIR-M, and hybrid-IR (p<0.001). Depictions of six arteries on axial, three arteries on MPR, and four arteries on VR images were significantly superior in the DLIR-M or hybrid-IR than in the DLIR-H (p≤0.009 for each). Diagnostic acceptability was significantly better in the DLIR-M and DLIR-H than in the hybrid-IR (p<0.001-0.005). CONCLUSION: DLIR-M showed well-balanced arterial depictions and image quality compared with the hybrid-IR and DLIR-H.

4.
Clin Oncol (R Coll Radiol) ; 35(10): e601-e610, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37587000

RESUMO

AIMS: To evaluate computed tomography (CT) and 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) findings of invasive non-mucinous adenocarcinoma (INMA) of the lung as a predictor of histological tumour grade according to 2021 World Health Organization (WHO) classification. MATERIALS AND METHODS: This retrospective study included consecutive patients with surgically resected INMA who underwent both preoperative CT and 18F-FDG-PET/CT. A three-tiered tumour grade was performed based on the fifth edition of the WHO classification of lung tumours. CT imaging features and the maximum standardised uptake value (SUVmax) were compared among the three tumour grades. RESULTS: In total, 214 patients with INMA (median age 70 years; interquartile range 65-76 years; 123 men) were histologically categorised: 36 (17%) as grade 1, 102 (48%) as grade 2 and 76 (35%) as grade 3. Pure solid appearance was more frequent in grade 3 (83%) than in grades 1 (0%) and 2 (26%) (P < 0.001). The SUVmax of the entire tumour was higher in grade 3 than in grades 1 and 2 (P < 0.001). Multivariable analysis revealed that pure solid appearance (odds ratio = 94.0; P < 0.001), round/oval shape (odds ratio = 4.01; P = 0.001), spiculation (odds ratio = 2.13; P = 0.04), air bronchogram (odds ratio = 0.40; P = 0.03) and SUVmax (odds ratio = 1.45; P < 0.001) were significant predictors for grade 3 INMAs. CONCLUSION: Pure solid appearance, round/oval shape, spiculation, absence of air bronchogram and high SUVmax were associated with grade 3 INMAs. CT and 18F-FDG-PET/CT were potentially useful non-invasive imaging methods to predict the histological grade of INMAs.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Masculino , Humanos , Idoso , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/cirurgia , Tomografia Computadorizada por Raios X , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Biomarcadores , Organização Mundial da Saúde , Pulmão
5.
Clin Radiol ; 77(2): e138-e146, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34782114

RESUMO

AIM: To evaluate the computed tomography (CT) attenuation values, background noise, arterial depiction, and image quality in whole-body dual-energy CT angiography (DECTA) at 40 keV with a reduced iodine dose using deep-learning image reconstruction (DLIR) and compare them with hybrid iterative reconstruction (IR). MATERIAL AND METHODS: Whole-body DECTA with a reduced iodine dose (200 mg iodine/kg) was performed in 22 patients, and DECTA data at 1.25-mm section thickness with 50% overlap were reconstructed at 40 keV using 40% adaptive statistical iterative reconstruction with Veo (hybrid-IR group), and DLIR at medium and high levels (DLIR-M and DLIR-H groups). The CT attenuation values of the thoracic and abdominal aortas and iliac artery and background noise were measured. Arterial depiction and image quality on axial, multiplanar reformatted (MPR), and volume-rendered (VR) images were assessed by two readers. Quantitative and qualitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups. RESULTS: The vascular CT attenuation values were almost comparable between the three groups (p=0.013-0.97), but the background noise was significantly lower in the DLIR-H group than in the hybrid-IR and DLIR-M groups (p<0.001). The arterial depictions on axial and MPR images and in almost all arteries on VR images were comparable (p=0.14-1). The image quality of axial, MPR, and VR images was significantly better in the DLIR-H group (p<0.001-0.015). CONCLUSION: DLIR significantly reduced background noise and improved image quality in DECTA at 40 keV compared with hybrid-IR, while maintaining the arterial depiction in almost all arteries.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Aprendizado Profundo , Iodo , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Corporal Total/métodos
6.
Clin Radiol ; 76(9): 710.e15-710.e24, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33879322

RESUMO

AIM: To evaluate the use of deep-learning-based image reconstruction (DLIR) algorithms in dynamic contrast-enhanced computed tomography (CT) of the abdomen, and to compare the image quality and lesion conspicuity among the reconstruction strength levels. MATERIALS AND METHODS: This prospective study included 59 patients with 373 hepatic lesions who underwent dynamic contrast-enhanced CT of the abdomen. All images were reconstructed using four reconstruction algorithms, including 40% adaptive statistical iterative reconstruction-Veo (ASiR-V) and DLIR at low, medium, and high-strength levels (DLIR-L, DLIR-M, and DLIR-H, respectively). The signal-to-noise ratio (SNR) of the abdominal aorta, portal vein, liver, pancreas, and spleen and the lesion-to-liver contrast-to-noise ratio (CNR) were calculated and compared among the four reconstruction algorithms. The diagnostic acceptability was qualitatively assessed and compared among the four reconstruction algorithms and the conspicuity of hepatic lesions was compared between <5 and ≥5 mm lesions. RESULTS: The SNR of each anatomical structure (p<0.0001) and CNR (p<0.0001) were significantly higher in DLIR-H than the other reconstruction algorithms. Diagnostic acceptability was significantly better in DLIR-M than the other reconstruction algorithms (p<0.0001). The conspicuity of hepatic lesions was highest when using 40% ASiR-V and tended to lessen as the reconstruction strength level was getting higher in DLIR, especially in <5 mm lesions; however, all hepatic lesions could be detected. CONCLUSIONS: DLIR improved the SNR, CNR, and image quality compared with 40% ASiR-V, while making it possible to decrease lesion conspicuity using higher reconstruction strength.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Meios de Contraste , Aprendizado Profundo , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Abdominal/métodos
7.
Biofizika ; 60(1): 88-94, 2015.
Artigo em Russo | MEDLINE | ID: mdl-25868345

RESUMO

Electron spin resonance (ESR) studies were carried out for 14N-labeled deuterated 3-methoxy-carbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) and 3-carboxy-2,2,5,5-tetramethyl-1-pyrrolidin-1-oxyl (carboxy-PROXYL) in pure water and various concentrations of liposomal solutions by using 300 MHz ESR spectrometer. The ESR parameters such as the line width, hyperfine coupling constant, rotational correlation time, g-factor, partition parameter and permeability were reported for the samples. The line width broadening was observed for MC-PROXYL and carboxy-PROXYL in liposomal solution. The hyperfine coupling constant was observed for both nitroxyl spin probes. The permeable and impermeable nature of nitroxyl spin probes was demonstrated. The rotational correlation time increases with increasing concentration of liposome. The partition parameter increases with increasing concentration of liposome for MC-PROXYL, which indicates that the nitroxyl spin probes diffuse into lipid membrane. The permeability value decreases with increasing concentration of liposome, which reveals an increase in membrane permeability. The peaks corresponding to the lipid phase were observed for MC-PROXYL in liposomal solution, but not resolved for carboxy-PROXYL. These results confirm the permeable and impermeable nature of nitroxyl spin probes.


Assuntos
Bicamadas Lipídicas/química , Óxidos de Nitrogênio/química , Marcadores de Spin , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Permeabilidade
8.
Int J Immunopathol Pharmacol ; 24(1 Suppl): 11S-16S, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21329560

RESUMO

Silicosis patients suffer from pulmonary fibrosis caused by silica inhalation, as well as autoimmune diseases known as the adjuvant effects of silica. Caplan syndrome complicated with rheumatoid arthritis (RA) is well known epidemiologically, and the incidence of complicated systemic sclerosis (SSc), systemic lupus erythematosus (SLE) and antineutrophilic cytoplasmic antibody (ANCA)-related nephritis have been reported frequently in silicosis patients. To explore the detailed mechanisms of silica-induced dysregulation of autoimmunity, we had focused on Fas/CD95 and Fas-mediated apoptosis because Fas is one of the most important molecules regarding apoptosis of lymphocytes and its alteration makes some T cells survive longer. Additionally, if the long-survived T cells include the self-recognizing T-cell clones, it is easily thought that autoimmune diseases will appear in this situation. Furthermore, regulatory T cells (Treg) showing CD4+25+ and forkhead box P3 (FoxP3)-positive have been a central player in regulating activation of self- and foreign-antigen recognizing T cells, and it has been reported that activation of Treg causes its higher expression of Fas/CD95. Thus, in this review, we introduce the alteration of Fas and related molecules as found in silicosis and also present the Treg function of the CD4+25+ fraction in peripheral blood mononuclear cells derived from silicosis patients.


Assuntos
Apoptose/efeitos dos fármacos , Autoimunidade/efeitos dos fármacos , Dióxido de Silício/toxicidade , Silicose/imunologia , Linfócitos T/efeitos dos fármacos , Receptor fas/fisiologia , Animais , Humanos , Linfócitos T/citologia , Linfócitos T/imunologia , Linfócitos T Reguladores/efeitos dos fármacos , Linfócitos T Reguladores/imunologia
9.
Methods Mol Biol ; 610: 29-39, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20013170

RESUMO

The partial pressure of oxygen (pO(2)) plays a determining role in the energy metabolism of aerobic cells. However, low pO(2) level induces pathophysiological conditions such as tumor hypoxia, ischemia or reperfusion injury, and delayed/altered wound healing. Especially, pO(2) level in the tumor is known to be related to tumor progression and effectiveness of radiotherapy. To monitor the pO(2) levels in vivo, continuous wave (CW) and time-domain (TD) electron paramagnetic resonance (EPR) spectroscopy method was used, in which surface coil resonator and Lithium phthalocyanine (LiPc) as oxygen sensor were crucial. Once LiPc particles are embedded in a desired location of organ/tissue, the pO(2) level can be monitored repeatedly and non-invasively. This method is based on the effect of oxygen concentration on the EPR spectra of LiPc which offers several advantages as follows: (1) high sensitivity, (2) minimum invasiveness, (3) repeated measurements, (4) absence of toxicity (non-toxic), and (5) measurement in a local region of the tissue with embedded LiPc. Therefore, in this chapter, we describe the method using CW and TD EPR spectroscopy with oxygen-sensitive particle, LiPc, for in vivo monitoring of oxygen.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Indóis/química , Compostos Organometálicos/química , Oximetria/métodos , Oxigênio/química , Animais , Dióxido de Carbono/química , Dióxido de Carbono/metabolismo , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Feminino , Camundongos , Micro-Ondas , Estrutura Molecular , Neoplasias/química , Neoplasias/metabolismo , Oximetria/instrumentação , Oxigênio/metabolismo , Consumo de Oxigênio , Radiossensibilizantes/química , Radiossensibilizantes/metabolismo , Marcadores de Spin
10.
J Magn Reson ; 190(2): 248-54, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18042414

RESUMO

Time-domain (TD) electron paramagnetic resonance (EPR) imaging at 300MHz for in vivo applications requires resonators with recovery times less than 1 micros after pulsed excitation to reliably capture the rapidly decaying free induction decay (FID). In this study, we tested the suitability of the Litz foil coil resonator (LCR), commonly used in MRI, for in vivo EPR/EPRI applications in the TD mode and compared with parallel coil resonator (PCR). In TD mode, the sensitivity of LCR was lower than that of the PCR. However, in continuous wave (CW) mode, the LCR showed better sensitivity. The RF homogeneity was similar in both the resonators. The axis of the RF magnetic field is transverse to the cylindrical axis of the LCR, making the resonator and the magnet co-axial. Therefore, the loading of animals, and placing of the anesthesia nose cone and temperature monitors was more convenient in the LCR compared to the PCR whose axis is perpendicular to the magnet axis.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Cauda/irrigação sanguínea , Animais , Feminino , Processamento de Imagem Assistida por Computador/instrumentação , Camundongos , Camundongos Endogâmicos C3H , Imagens de Fantasmas , Sensibilidade e Especificidade , Marcadores de Spin , Avaliação da Tecnologia Biomédica
11.
Mol Phylogenet Evol ; 45(1): 239-50, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17714956

RESUMO

The evolution of fungus-growing termites is supposed to have started in the African rain forests with multiple invasions of semi-arid habitats as well as multiple invasions of the Oriental region. We used sequences of the mitochondrial COII gene and Bayesian dating to investigate the time frame of the evolution of Macrotermes, an important genus of fungus-growing termites. We found that the genus Macrotermes consists of at least 6 distantly related clades. Furthermore, the COII sequences suggested some cryptic diversity within the analysed African Macrotermes species. The dates calculated with the COII data using a fossilized termite mound to calibrate the clock were in good agreement with dates calculated with COI sequences using the split between Locusta and Chortippus as calibration point which supports the consistency of the calibration points. The clades from the Oriental region dated back to the early Tertiary. These estimates of divergence times suggested that Macrotermes invaded Asia during periods with humid climates. For Africa, many speciation events predated the Pleistocene and fall in range of 6-23 million years ago. These estimates suggest that savannah-adapted African clades radiated with the spread of the semi-arid ecosystems during the Miocene. Apparently, events during the Pleistocene were of little importance for speciation within the genus Macrotermes. However, further investigations are necessary to increase the number of taxa for phylogenetic analysis.


Assuntos
Especiação Genética , Isópteros/genética , Fatores de Tempo , Animais , Complexo IV da Cadeia de Transporte de Elétrons/análise , Complexo IV da Cadeia de Transporte de Elétrons/genética , Evolução Molecular , Modelos Biológicos , Filogenia
12.
Isotopes Environ Health Stud ; 36(3): 259-72, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11501704

RESUMO

Nitrogen and carbon stable isotope ratios and uric acid concentrations in termites sampled from a dry evergreen forest in Thailand, were determined across three kinds of feeding habits. Feeding habits of Microcerotermes crassus, which is an abundant wood-feeder, and Dicuspiditermes makhamensis, a common soil-feeding termite, were confirmed by isotopic signatures. Lichen feeding termites (Hospitalitermes birmanicus, H. bicolor and H. ataramensis) were characterized by low delta15N values, suggesting that they assimilated nitrogen deposited from the atmosphere. There was also a significant difference in uric acid concentrations between termites representing different feeding habits. No significant relationships were found between uric acid concentrations and delta15N or delta13C in Hospitalitermes. However, delta15N values were correlated with C/N ratios in H. birmanicus, except in one colony of H. ataramensis. delta13C values in both species were negatively correlated with C/N ratios.


Assuntos
Isótopos de Carbono/análise , Comportamento Alimentar , Isópteros , Isópteros/química , Isótopos de Nitrogênio/análise , Ácido Úrico/análise , Animais , Isópteros/fisiologia , Líquens/química , Solo , Tailândia , Árvores , Madeira
13.
Int J Urol ; 5(3): 282-7, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9624562

RESUMO

BACKGROUND: A new human testicular cancer cell line (JKT-1) was established, successfully transplanted into nude mice, and has been maintained for over 2 years. We examined the biological characteristics of JKT-1 cells. METHODS: The original material for JKT-1 was derived from a primary lesion of a left testicular seminoma (pure, typical-type) from a 40-year-old male. The tumor tissue was minced and cultured according to the explant culture method. The cells grew as a monolayer with a doubling time of 28.5 hours. RESULTS: JKT-1 produced neither alpha-fetoprotein or beta-human chorionic gonadotropin, but showed strong immunoreactivities for vimentin and placental alkaline phosphatase. A chromosomal analysis revealed a modal number of 66 with loss of the Y chromosome. Morphologically, JKT-1 cells have a pleomorphic polygonal shape, an increase in the nuclear/cytoplasm ratio, and poor development of organelle and desmosome-like cell-cell junctions. JKT-1 cells were subcutaneously transplanted into the backs of 6-week-old nude mice, and grew classical seminomatous tissue. CONCLUSION: This report profiled a seminoma cell line established for both in vitro and in vivo experimental systems. Future studies are planned to investigate germ cells using this seminoma line.


Assuntos
Seminoma/patologia , Neoplasias Testiculares/patologia , Adulto , Fosfatase Alcalina/metabolismo , Animais , Mapeamento Cromossômico , Humanos , Imuno-Histoquímica/métodos , Masculino , Camundongos , Camundongos Nus , Transplante de Neoplasias , Placenta/enzimologia , Seminoma/genética , Seminoma/metabolismo , Coloração e Rotulagem , Neoplasias Testiculares/genética , Neoplasias Testiculares/metabolismo , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...